High-throughput and high peak capacity narrow-bore parallel segmented flow 2 column strategy for the liquid chromatography - tandem mass spectrometry 3 analysis of organic contaminants in water

Tema

AGUAS
CONTAMINANTES ORGANICOS
CROMATOGRAFIA LIQUIDA
ESPECTROMETRIA DE MASA
BIBLIOGRAFIA NACIONAL QUIMICA
2020

Abstract

This study highlights the development of a high peak capacity, high-throughput (HTP) approach for a target list of 62 organic contaminants in an environmental river water matrix on a HPLC conventional 400 bar system. Key separation metrics were evaluated: (a) peak capacity, (b) total analysis time and (c) mobile phase consumption. An average peak width of 0.10 min with a total analysis time (inclusive of the column wash and re-equilibration) of 10 minutes revealed the increased productivity and performance of the parallel segmented flow (PSF) column technology HPLC-MS strategy, comparable to UHPLC peak widths and analysis times, achieved at a significantly lower backpressure (<400 bar). The operation of the PSF in a narrow-bore scale format (internal diameter of 2.1 mm) resulted in a conservative HPLC scale total mobile phase consumption of 15 mL for the column separation; only 5.5 mL of this volume was exposed to the ion source per injection. Mobile phase consumption was higher compared to that of UHPLC, but on the other hand it achieved higher peak capacity. Three representative compounds (atrazine, diclofenac and fluazuron) with differing retention and ionisation properties were studied in detail in terms of detection sensitivity. The majority of the ion ratios for the standards in the river water matrix were within ±30% of the average ion ratios. The largest ion suppression occurred for atrazine (−25% matrix effect), a pesticide notorious for poor ionization and poor peak shape issues. The lowest response transitions at 1 μg L−1 for the extracted ions in the river water matrix of atrazine, diclofenac and fluazuron had signal to noise ratios ≥3, with the exception of diclofenac where 5 μg L−1 was the lowest calibration level. The peak area's calibration curve slope and standard deviation in the detector's response determination of limit of quantification (LOQ) were between 5.2 and 30.4 μg L−1.

Autor

Soliven, Arianne
Pareja, Lucía
Shalliker, Andrew
Heinzen, Horacio
Pérez Parada, Andrés

Fuente

Analytical Methods V.12, NO. 3, 2020. -- P.239-246

Editor

Royal Society of Chemistry

Fecha

2020

Derechos

Información sobre Derechos de Autor (Por favor lea este aviso antes de abrir los documentos u objetos) La legislación uruguaya protege el derecho de autor sobre toda creación literaria, científica o artística, tanto en lo que tiene que ver con sus derechos morales, como en lo referente a los derechos patrimoniales con sujeción a lo establecido por el derecho común y las siguientes leyes (LEY 9.739 DE 17 DE DICIEMBRE DE 1937 SOBRE PROPIEDAD LITERARIA Y ARTISTICA CON LAS MODIFICACIONES INTRODUCIDAS POR LA LEY DE DERECHO DE AUTOR Y DERECHOS CONEXOS No. 17.616 DE 10 DE ENERO DE 2003, LEY 17.805 DE 26 DE AGOSTO DE 2004, LEY 18.046 DE 24 DE OCTUBRE DE 2006 LEY 18.046 DE 24 DE OCTUBRE DE 2006) ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso: Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con fines de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes debe indicarse el nombre de la persona autora.

Formato

Pdf

Idioma

Ingés

Tipo

Artículo

Identificador

DOI: 10.1039/C9AY02370D

Document Item Type Metadata

Original Format

Pdf
Fecha de agregación
May 12, 2020
Colección
Bibliografía Nacional Química
Tipo de Elemento
Document
Etiquetas
, , ,
Citación
Soliven, Arianne, “High-throughput and high peak capacity narrow-bore parallel segmented flow 2 column strategy for the liquid chromatography - tandem mass spectrometry 3 analysis of organic contaminants in water,” RIQUIM - Repositorio Institucional de la Facultad de Química - UdelaR, accessed April 19, 2024, https://riquim.fq.edu.uy/items/show/6061.
Archivos