Analytical improvements of hybrid LC-MS/MS techniques for the efficient evaluation of emerging contaminants in river waters : a case study of the Henares River (Madrid, Spain)

Dublin Core

Título

Analytical improvements of hybrid LC-MS/MS techniques for the efficient evaluation of emerging contaminants in river waters : a case study of the Henares River (Madrid, Spain)

Tema

CONTAMINANTES DEL AGUA
ESPAÑA
RIO HENARES
CROMATOGRAFIA LIQUIDA
BIBLIOGRAFIA NACIONAL QUIMICA
2012

Abstract

Purpose Instrumental capabilities and software tools of modern hybrid mass spectrometry (MS) instruments such as high-resolution mass spectrometry (HRMS), quadrupole time-of-flight (QTOF), and quadrupole linear ion trap (QLIT) were experimentally investigated for the study of emerging contaminants in Henares River water samples. Methods Automated screening and confirmatory capabilities of QTOF working in full-scan MS and tandem MS (MS/MS) were explored when dealing with real samples. Investigations on the effect of sensitivity and resolution power influence on mass accuracy were studied for the correct assignment of the amoxicillin transformation product 5(R) amoxicillin-diketopiperazine-2′,5′ as an example of a nontarget compound. On the other hand, a comparison of quantitative and qualitative strategies based on direct injection analysis and off-line solid-phase extraction sample treatment were assayed using two different QLIT instruments for a selected group of emerging contaminants when operating in selected reaction monitoring (SRM) and information-dependent acquisition (IDA) modes. Results and discussion Software-aided screening usually needs a further confirmatory step. Resolving power and MS/MS feature of QTOF showed to confirm/reject most findings in river water, although sensitivity-related limitations are usually found. Superior sensitivity of modern QLIT-MS/MS offered the possibility of direct injection analysis for proper quantitative study of a variety of contaminants, while it simultaneously reduced the matrix effect and increased the reliability of the results. Confirmation of ethylamphetamine, which lacks on a second SRM transition, was accomplished by using the IDA feature. Conclusion Hybrid MS instruments equipped with high resolution and high sensitivity contributes to enlarge the scope of targeted analytes in river waters. However, in the tested instruments, there is a margin of improvement principally in required sensitivity and data treatment software tools devoted to reliable confirmation and improved automated data processing.

Autor

Gómez-Ramos, María del Mar
Martínez Bueno, María Jesús
Uclés, Samanta
Fernández Alba, Amadeo R

Fuente

Environmental Science and Pollution Research International v. 19, no. 2, 2012. -- p. 467-481

Editor

Springer-Verlag

Fecha

2012-08-16

Derechos

Información sobre Derechos de Autor

(Por favor lea este aviso antes de abrir los documentos u objetos)

La legislación uruguaya protege el derecho de autor sobre toda creación literaria, científica o artística, tanto en lo que tiene que ver con sus derechos morales, como en lo referente a los derechos patrimoniales con sujeción a lo establecido por el derecho común y las siguientes leyes

(LEY 9.739 DE 17 DE DICIEMBRE DE 1937 SOBRE PROPIEDAD LITERARIA Y ARTISTICA CON LAS MODIFICACIONES INTRODUCIDAS POR LA LEY DE DERECHO DE AUTOR Y DERECHOS CONEXOS No. 17.616 DE 10 DE ENERO DE 2003, LEY 17.805 DE 26 DE AGOSTO DE 2004, LEY 18.046 DE 24 DE OCTUBRE DE 2006 LEY 18.046 DE 24 DE OCTUBRE DE 2006)

ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso: Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con fines de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes debe indicarse el nombre de la persona autora.

Formato

PDF

Idioma

Inglés

Tipo

Artículo

Identificador

DOI 10.1007/s11356-011-0585-2

Document Item Type Metadata

Original Format

PDF
Fecha de agregación
August 16, 2012
Colección
Bibliografía Nacional Química
Tipo de Elemento
Document
Etiquetas
,
Citación
Pérez Parada, Andrés, “Analytical improvements of hybrid LC-MS/MS techniques for the efficient evaluation of emerging contaminants in river waters : a case study of the Henares River (Madrid, Spain),” RIQUIM - Repositorio Institucional de la Facultad de Química - UdelaR, accessed March 29, 2024, https://riquim.fq.edu.uy/items/show/106.
Archivos